Fire Alarm Hong Chang / Horinglih Origin Taiwan

Fire Alarm Control Panel Model HC-5AL / HC-10AL

Features :

  • Alarm verification: To avoid false alarm from environment interference and unstable pulse. On receiving a fire signal from detector or manual call point, Panel accumulates the fire signal before alarm verification time : 12 seconds, if the fire signal is still existing, Panel start to alert.
  • Zone test : Alarm and fault function test.
  • Back up battery test.
  • Fault indications for wire disconnection, unstable AC power, battery short circuit or disconnection and fuse trouble.
  • Different sounds to indicate fire alarm or disconnection.
  • Annunciator is available to connect with.
firealarm 20zone

The panel system is microcomputer designed for fire alarm, smoke exhaust, water sprinkle, fire-fighting foam control.

All PCB are based on modules and stable, easy replace and maintaince. Auto test function makes it easy to check and control.

Fire Alarm Control Panel

Function :

  • Alarm verification, double check the fire alarm signal to avoid false alarm
  • Battery self-protect, battery is running lower 18VDC, it will stop discharging.
  • Indication LED, different color light to indicate different condition.
  • Loop auto test and manual test, test loop from 1 to the last automatically or set a certain loop manually to test.
  • Annunciator panel is available.
fire alarm 2
fire alarm 3
fire alarm 3 1
fire alarm 3 2
Optical Photoelectric Smoke Detector for 12VDC Security System Produk
Optical Photoelectric Smoke Detector for 12VDC Security System

Optical (Photoelectric) Smoke Detector- for 12VDC Security System

Features :

  • 12VDC input power, can be combined with security/ burglar system
  • Relay contact (1A) : N/C (normal/close); N/O (normal/open) alternative.
  • With a button on the surface, when the detector alarms, the LED signal will hold until press the button.
Sensing Way
Optical(Photoelectric )smoke detector responds to smoke. It has a chamber inside consists of a “light-emitting diode (LED)” that constantly shoots a beam of light and a “photocell” that senses light from darkness. In peacetime, the “photocell”can not senses the beam of light form the “light-emitting diode (LED)”. When there is smoke into the chamber of detector ,the beam of light is scattered by smoke particles, and the scattered light hit the“photocell”, thus the alarm is initiated.
Optical Photoelectric Smoke Detector for 12VDC Security System Produk
Ionization Smoke Detector for 12VDC Security System Specification

Ionization Smoke Detector- for 12VDC Security System

Features :

  • 12VDC input power, can be combined with security/ burglar system
  • Relay contact (1A) : N/C (normal/close); N/O (normal/open) alternative.
  • With a button on the surface, when the detector alarms, the LED signal will hold until press the button.

Sensing Way

Ionization smoke detector responds to smoke. It has an ionization chamber inside. The ionization chamber with ions in it will generate a constant, small electric current.When smoke enters this detector, the smoke particles attach to the ions inside the chamber and neutralize them. That will cause the current inside the chamber drop, therefore trigger the detector alarm.
Fire Alarm Bell Motor Driven Produk
Fire Alarm Bell Motor Driven spek 2

Fire Alarm Bell-Motor Driven (HC-624B / HC-824B / HC-1024B)

Features :

  • UL APPROVED
  • HIGH dbA OUTPUT
  • LOW POWER CONSUMPTION
  • AVAILABLE IN 6” ,8” ,10” HOUSING
  • QUICKLY AND EASILY INSTALLED

Installation Note

  1. Remove the gong.
  2. Wire the bell in the circuit.
  3. Mount bell mechanism on 4″ square standard outlet box with the striker facing down.
  4. Remove a gong.
  5. The bell must be mounted a minimum of 8ft., above the floor, or, as close to the ceiling as possible.
  6. Polarized bell provides Red(-) and Black(-) lead wires. When you install the bell, must be observed the polarity.
Fire Alarm Bell Motor Driven Spek
Rate of Rise Heat Detector
Rate of Rise Heat Detector General Wiring

Rate of Rise Heat Detector HC-306A

Features :

  • With dual LED, easy to observe state of detector.
  • The dual LED light up constantly when the detector alarms.
  • With large metal surface to expose the air to sense the temperature.

Installation Note

  1. Remove the gong.
  2. Wire the bell in the circuit.
  3. Mount bell mechanism on 4″ square standard outlet box with the striker facing down.
  4. Remove a gong.
  5. The bell must be mounted a minimum of 8ft., above the floor, or, as close to the ceiling as possible.
  6. Polarized bell provides Red(-) and Black(-) lead wires. When you install the bell, must be observed the polarity.
Rate of Rise Heat Detector sPEK